Section / 02 / 03

Freestanding Convector

Floor-standing casing, natural convection, for rooms without a recess.

Family
03
Profile
Floor-standing
Casings
Series 01 / Series 02
Custom
Yes
Freestanding copper-tube convector in a floor-standing casing
Plate 03Freestanding convector — floor-standing casing

Construction

The casing stands on its own brackets against the wall or beneath the window, so no recess is needed.

  • Casing height set to clear the sill or the glazing frame.
  • Removable front panel for cleaning and access to the connection.
Configuration
ProfileFloor-standing
CasingSPCC cold-rolled steel, 1.2 mm
ConvectionNatural
Length and heightMade to the required dimensions
ConnectionSide (C) or bottom (D); DN15 / DN20

Dimensions and heat output are issued per order against the drawing.

Casings

Two casings, one family

Both casings are built to the required length and height. The difference is the casing itself and how the connections and valves are treated at the end.

Series 01

Compact enclosure, exposed connections

Side and bottom connection options allow the unit to be coordinated with the project's pipework, while leaving the connection area accessible for installation and servicing.

  • Side or bottom connection — C (side in/out) or D (bottom in/out) in the model designation.
  • Left in/out or right in/out; top supply and bottom return.
  • DN15 and DN20 for side and bottom connections; special connection sizes on request.
Freestanding Series 01 casing end with two brass side connection ports
VisualisationSide ports at the casing end.
Series 01 Data sheet · 5 pp · 4.1 MB →
Series 02

Concealed pipework, hidden valve

The pipework and valves are concealed within the connection area for a clean, coordinated appearance. The rounded enclosure suits residential, commercial and public interiors where visible detailing is an important part of the design.

  • Hidden valve design, reachable for control.
  • Concealed piping; rounded, sharp-free edges.
  • Precision connection design at the casing end.
Freestanding Series 02 casing with the end panel removed, showing the valve and pipework inside
VisualisationEnd panel off: valve and pipework sit inside the casing.
Series 02 Data sheet · 5 pp · 0.3 MB →

Both sheets give the natural-convection version. A fan-assisted unit is made to order and its figures are issued with the quotation.

Configurations

Variants

NC

Natural convection

The usual choice in a room where the run is long enough and silence matters. Built in either casing — Series 01 with the connections exposed, Series 02 with the pipework and valve concealed. See Casings above.

Convection
Natural
Media
Heating water
FC

Forced convection

Adds a fan where the room has a short length of wall and the load does not fall.

Convection
Fan-assisted
Media
Heating water

In place

A drawing, a schedule or a photograph of the unit being replaced is enough to quote against.

Enquire about this family